Rat & Hilfe 
  Artikelsuche
Häufig gestellte Fragen
Fallstudien
 

Why are the Charpy impact values from my test welds lower than that printed on your Certificate of Conformance?


The test results on our Certificate of Conformance were obtained from welding an AWS filler metal test plate. Any change in welding procedure will affect Charpy impact values. Below are common practices for welding test plates when Charpy impact specimens are required:

1. Controlled heat input

2. Controlled preheat and interpass temperature

3. Even number of passes per layer

4. Build-up cap pass to maximum allowed in specification "

 